Schneider Electric Contactor EasyPact TVS, 3P(3NO), AC-3 <=440V, 80A, 230V AC coil 50/60Hz; LC1E80P7
Contactor EasyPact TVS, 3P(3NO), AC-3 <=440V, 80A, 230V AC coil 50/60Hz; LC1E80P7...
VAT-exclusive price: 12.355,00 |
VAT-inclusive price: 14.826,00 |
Contactor EasyPact TVS, 3P(3NO), AC-3 <=440V, 80A, 230V AC coil 50/60Hz; LC1E80P7
Range | EasyPact |
---|---|
Product or component type | Contactor |
Device short name | LC1E |
Contactor application |
Resistive load Motor control |
Utilisation category |
AC-3 AC-1 |
Poles description | 3P |
[Ue] rated operational voltage | Power circuit: <= 690 V AC 50/60 Hz |
[Ie] rated operational current |
80 A (at <55 °C) at <= 440 V AC AC-3 for power circuit 110 A (at <55 °C) at <= 440 V AC AC-1 for power circuit |
[Uc] control circuit voltage | 230 V AC 50/60 Hz |
Motor power kW |
22 kW at 220...230 V AC 50/60 Hz 37 kW at 380...400 V 45 kW at 415 V 45 kW at 440 V 45 kW at 500 V 45 kW at 660...690 V |
---|---|
Pole contact composition | 3 NO |
[Ith] conventional free air thermal current | 100 A (at 60 °C) for power circuit |
Irms rated making capacity | 800 A at 440 V AC for power circuit conforming to IEC 60947-4-1 |
Rated breaking capacity | 640 A at 440 V for power circuit conforming to IEC 60947 |
[Icw] rated short-time withstand current |
640 A 40 °C - 10 s for power circuit 320 A 40 °C - 60 s for power circuit 135 A 40 °C - 600 s for power circuit |
Associated fuse rating |
10 A gG at <= 690 V coordination type 1 for control circuit conforming to IEC 60947-5-1 160 A gG at <= 690 V coordination type 1 for power circuit |
Average impedance | 0.8 mOhm - Ith 110 A 50 Hz for power circuit |
Power dissipation per pole |
5.1 W AC-3 9.7 W AC-1 |
[Ui] rated insulation voltage | 690 V conforming to IEC 60947-4-1 |
Overvoltage category | III |
Pollution degree | 3 |
[Uimp] rated impulse withstand voltage | 6 kV coil not connected to the power circuit conforming to IEC 60947 |
Mechanical durability | 300000 cycles |
Electrical durability |
350000 cycles AC-1 900000 cycles AC-3 |
Control circuit type | AC at 50/60 Hz |
Control circuit voltage limits |
0.85...1.1 Uc (55 °C):operational 50/60 Hz 0.3...0.6 Uc (55 °C):drop-out 50/60 Hz |
Inrush power in VA |
200 VA 50 Hz cos phi 0.75 (at 20 °C) 220 VA 60 Hz cos phi 0.75 (at 20 °C) |
Hold-in power consumption in VA |
22 VA 60 Hz cos phi 0.3 (at 20 °C) 20 VA 50 Hz cos phi 0.3 (at 20 °C) |
Heat dissipation | 6…10 W for control circuit |
Operating time |
20...35 ms on closing 6...30 ms on opening |
Maximum operating rate | 1200 cyc/h 60 °C |
Connections - terminals |
Control circuit: screw clamp terminals 1 1…4 mm² - cable stiffness: flexible without cable end Control circuit: screw clamp terminals 2 1…4 mm² - cable stiffness: flexible without cable end Control circuit: screw clamp terminals 1 1…4 mm² - cable stiffness: flexible with cable end Control circuit: screw clamp terminals 2 1…2.5 mm² - cable stiffness: flexible with cable end Control circuit: screw clamp terminals 1 1…4 mm² - cable stiffness: solid without cable end Control circuit: screw clamp terminals 2 1…4 mm² - cable stiffness: solid without cable end Power circuit: screw clamp terminals 1 4…50 mm² - cable stiffness: flexible with cable end Power circuit: screw clamp terminals 2 4…16 mm² - cable stiffness: flexible with cable end Power circuit: screw clamp terminals 1 4…50 mm² - cable stiffness: solid without cable end Power circuit: screw clamp terminals 2 4…50 mm² - cable stiffness: solid without cable end |
Tightening torque |
Control circuit: 1.2 N.m Power circuit: 12 N.m |
Auxiliary contact composition | 1 NO + 1 NC |
Minimum switching voltage | 17 V for control circuit |
Minimum switching current | 5 mA for control circuit |
Insulation resistance | > 10 MOhm for control circuit |
Non-overlap time |
1.5 ms on energisation guaranteed between NC and NO contact 1.5 ms on de-energisation guaranteed between NC and NO contact |
Mounting support |
DIN rail Plate |
Standards |
IEC 60947-4-1 IEC 60947-5-1 IEC 60947-1 |
---|---|
Product certifications |
CE EAC |
IP degree of protection | IP2X conforming to IEC 60529 |
Protective treatment | TH (pollution degree 3) conforming to IEC 60068-2-30 |
Permissible ambient air temperature around the device |
-20…70 °C at Uc -60…80 °C storage -5…55 °C operation |
Operating altitude | 3000 m without derating |
Fire resistance | 850 °C conforming to IEC 60695-2-1 |
Mechanical robustness |
Vibrations contactor open (1.5 Gn, 5...300 Hz) Vibrations contactor closed (3 Gn, 5...300 Hz) Shocks contactor open (6 Gn for 11 ms) Shocks contactor closed (7 Gn for 11 ms) |
Height | 127 mm |
Width | 85 mm |
Depth | 121 mm |
Net weight | 1.52 kg |
Similar products:
Schneider Electric EasyPact 6 A LC1E kontaktor 3P(3 NO) AC-3 <=440V 6A 230V AC kalem
Schneider Electric EasyPact LC1E contactor 3P(3 NO) AC-3 <=440V 6A 230V AC coil
-

(Out of stock)
1.907,00
Schneider Electric EasyPact LC1E 9 Amp kontaktor 3P(3 NO) AC-3 <=440V 9A 230V AC kalem
Schneider Electric EasyPact LC1E 9 Amp contactor 3P(3 NO) AC-3 <=440V 9A 230V AC coil
-

(Out of stock)
2.080,00
Schneider Electric EasyPact TVS: Kontaktor, 3P, 40A (AC-3), kalem 230V AC, 1NO+1NC ; LC1E40P7
EasyPact TVS: contactor, 3P, 40A (AC-3), coil 230V AC, 1NO+1NC ; LC1E40P7
-

(Out of stock)
7.282,00
Schneider Electric EasyPact TVS 3P CONTACTOR 400V 22KW AC3 ; LC1E50P7
Schneider Electric EasyPact TVS 3P CONTACTOR 400V 22KW AC3 - 230V AC coil ; LC1E50P7
-

(Out of stock)
7.363,00
Schneider Electric Kontaktor 3P TVS 65A 30kW 400V AC3 230V AC 1NO+1NC ; LC1E65P7
Contactor,EasyPact TVS,3P(3NO),AC-3,<=440V,65A,230V AC coil; LC1E65P7
-

(Out of stock)
8.757,00
Schneider Electric Contactor,EasyPact TVS,3P(3NO),AC-3,<=440V,80A,24V AC coil,50/60Hz; LC1E80B7
Contactor,EasyPact TVS,3P(3NO),AC-3,<=440V,80A,24V AC coil,50/60Hz; LC1E80B7
-

(Out of stock)
18.406,00